3P Solar Mini Circuit Breaker

3P Solar Mini Circuit Breaker

3P Solar Mini Circuit Breaker ETM3 3P Solar Mini Circuit Breaker 6A…63A 6KA .10KA breaking capacity Model: ETM3 3P Solar Mini Circuit Breaker ETM3 2P Solar Mini Circuit Breaker apply to the solar power systems or DC type electric system. This products exported to: KSA, UAE, YEMEN, IRQA,KENAY,......

Send InquiryChat Now

3P Solar Mini Circuit Breaker
ETM3 3P Solar Mini Circuit Breaker
6A…63A
6KA .10KA breaking capacity

Model: 
ETM3 3P Solar Mini Circuit Breaker
 
ETM3 2P Solar Mini Circuit Breaker apply to the solar power systems or DC type electric system.
This products exported to: KSA, UAE, YEMEN, IRQA,KENAY, NIGERIA, Ghana and so on.  Welcome to OEM and branding customers’ mark.

ETM3D DC  Mini Circuit Breaker

Frame Degree Rated Current(A)

63

Pole

1P,2P,3P,4P

Rated Operating Voltage(VDC)

DC12V-DC1200V

Rated Current In (A)

1-63A

Rated Insulation Voltage Ui (VDC)

1200VDC

Rated Impact Voltage Uimp (KV)

4

Ultimate Breaking Capacity Icu (KA)

10

Run Breaking Capacity Ics (%Icu)

75%

Curve Type

C

Trip Type

Thermal-magnetic

Mechanical

8500

Electric

2500


How to Select Proper MCB for different loads?
Choosing a particular MCB for a specific application is a careful task to ensure reliable protection against overloads and short circuits. If it is not selected according to the circuit requirements, there will be chances to lead frequent unwanted tripping. Before we going in details, We must know difference between MCB & MCCB, How to Read MCB Nameplate and difference between ELCB, RCB and RCD Circuit Breakers
 
If it is undersized (MCB rating less than the nominal load current), MCB causes frequent tripping and causes to interrupt the current to the load it is being connected, because the MCB nominal current less than nominal current value of the load. Similarly, if it is oversized (MCB rating more than the nominal load current), the load to it is connected will not be protected efficiently. In such case, the MCB will not trip even though load is drawing overcurrent.
image001.jpg
image003.jpg
image005.jpg

image009.jpg
image010.jpg
image011.jpg

image012.jpg

image012.jpg

If you are going to check the price with 3P Solar Mini Circuit Breaker, 3P DC MCB,manufacturer,supplier in China. Please feel free to contact us.

Hot Tags: 3P solar mini circuit breaker, China, suppliers, manufacturers, factory, customized, free sample, made in China
Related Products

24 hours at your service:

ivan@cnetec.com

Newsletter

  • Yueqing Etec Electric Co.,Ltd